Environmental sensing, liquid measurement and analysis.

Best Sale

Aecl Sensors Service Introduction

Autotronic Enterprise Co., Ltd. is Taiwan Sensors professional automation environmental sensing, liquid measuring system controller and signal converter consultant with more than 40 years experence. Since 1976, in the Industrial Equipment Industry, Aecl has been offering our customers high quality Sensors production and consultant service. With both advanced technology and 40 years experience, Aecl always make sure to meet each customer's demand.

Result 1 - 17 of 17
  • Temperature and Humidity Transmitter for high humidity environment
    Temperature and Humidity Transmitter for high humidity environment
    AHT503-H

    AHT-503H series Temperature and relative humidity(RH) Transmitter is perfect for high humidity environment. In high relative humidity (over 90% RH), the environmental temperature will be closed to the saturation. The vapor pressure gradient is not enough for effective evaporation of liquid. Thus, the sensor might stay wet and became malfunctioned. The AHT-503H transmitter equipped with special sintered sensing probe to protect the sensing elements and to avoid the measurement outage which might happen in the high humidity environment.AHT-503H adopted CMOSens technology sensors to ensure its stability and reliability of measurement, meanwhile, it equipped with 3 switchable temperature measurement range 0~50℃, -50~50℃ or 0~100℃ to enable users to deploy the transmitter in different environment. To timely monitor the temperature and RH variation, the temperature and humidity meter provide current signal DC 4~20mA, voltage signal DC 0~10V/0~5V/1~5V or digital RS485 Modbus RTU signal to transfer the IAQ data immediately to the energy monitoring system or BMS system.Most of the AHT-503H transmitters are used in the smart agriculture or poultry farming to monitor the growth environment of the plant or animal, for example, poultry farm. Furthermore, they are also used in cold chain and logistic to monitor the storage environment of food or products, for example, wine cellar or warehouse.


  • Oxygen (O2) Transmitter
    Oxygen (O2) Transmitter
    AVC-010

    AVC-010 Oxygen transmitter provides precise Oxygen measurement and several different signal outputs for options, RS485 and 2-10V/4-20mA output for real time data monitoring, analysis or for efficient ventilation control.Oxygen transmitter is widely used in the underground/indoor parking, hospital or library to prevent deadly harm caused by lack of Oxygen.


  • Carbon Dioxide (CO2) Transmitter (LoRa)
    Carbon Dioxide (CO2) Transmitter (LoRa)
    AVC-310

    AVC-310 Carbon Dioxide (CO2) Transmitter equipped with switchable RS485 (wire) and Lora (wireless) connection, which provide a higher flexibility of application. The wireless private LoRa transmitter could be simply installed and save more cost of installation.The CO2 transmitter also provides one dry contact relay output to trigger the backend alarm or ventilation devices to efficiently adjust the indoor air quality.


  • Carbon Monoxide (CO) Transmitter (LoRa)
    Carbon Monoxide (CO) Transmitter (LoRa)
    AVC-110

    AVC-110 Carbon monoxide (CO) Transmitter equipped with switchable RS485 (wire) and Lora (wireless) connection which provides a higher flexibility of application. Besides, one alarm relay output is provided for efficiently IAQ management and warning.It is widely used in underground parking, garage or basement to prevent deadly harm of high concentration of Carbon Monoxide. When the CO concentration is higher than the setting point, it can trigger alarm or to activate ventilation system to introduce fresh air.


  • PM2.5 Air Quality Transmitter (LoRa)
    PM2.5 Air Quality Transmitter (LoRa)
    AVC-210

    AVC-210 PM2.5 transmitter provides precise and reliable PM2.5 air measurement and accurately send data to the back end platform for real time data monitoring, analysis or for efficient ventilation control.It equipped with switchable RS485 (wire) and Lora (wireless) connection, which provide a higher flexibility of application. The wireless private LoRa transmitter could be simply installed and save more cost of installation.Knowing that Air Quality influence much on human health, more and more peopel start to use PM2.5 transmitters to efficiently monitor and ensure good indoor air quality.


  • PM10 Air Quality Transmitter (LoRa)
    PM10 Air Quality Transmitter (LoRa)
    AVC-510

    AVC-510 PM10 transmitters provide precise and reliable PM10 air measurement. The PM10 data can be accurately transferred via RS485 or LoRa to the back end platform for the real time data monitoring and analysis or be connected to the HVAC system and air purifier for efficient air quality improvement.Knowing that Air Quality influence much on human health, more and more people start to use PM10 transmitter to monitor and ensure good indoor air quality.


  • TVOC Air Quality Transmitter (LoRa)
    TVOC Air Quality Transmitter (LoRa)
    AVC-910

    VOCs are emitted as gases from certain solids or liquids, such as building materials and furnishings, office equipment, wood preservatives, cleansers and disinfectants, dry-cleaned clothing or stored fuels and automotive products, etc.AVC-910 air quality transmitter reliably measures the TVOC concentration, and sends signal to the monitoring center to control air purifying or ventilation system. To optimize the building performance and improve the indoor air quality efficiently.It equipped with switchable RS485 (wire) and Lora (wireless) connection, which provide a higher flexibility of application. The wireless private LoRa transmitter could be simply installed and save more cost of installation.


  • Oxygen (O2) Transmitter (LoRa)
    Oxygen (O2) Transmitter (LoRa)
    AVC-010

    AVC-010 Oxygen transmitter provides precise Oxygen measurement and switchable RS485 and LoRa signal output for real time data monitoring, analysis or for efficient ventilation control.Oxygen transmitter is widely used in the underground/indoor parking, hospital or library to prevent deadly harm caused by lack of Oxygen.


  • Heat (BTU) Meter & Calculator
    Heat (BTU) Meter & Calculator
    ABU

    Aecl BTU Heat meter is a stand- alone heat meter & calculator designed for energy consumption measurement in heating and cooling system.Basic calculation factors are flow rate and temperature value, which are getting from the flow sensor and temperature sensors installed in inlet and outlet pipes of HVAC system. And the energy consumption is calculated according a formula.In addition to real-time/ accumulated energy consumption, real-time/accumulated flow and temperature difference can also be recorded and displayed by ABU series heat meter.


  • Stainless Steel High Performance Flow Sensor
    Stainless Steel High Performance Flow Sensor
    2540

    The Signet 2540 Paddlewheel Flow Sensor offers the strength and corrosion-resistance of stainless steel for liquid applications with low velocity measurements. Unique internal circuitry eliminates the need for magnets in the process fluid, enabling flow measurement of 0.1 to 6 m/s (0.3 to 20 ft/s) while maintaining the advantages of insertion sensor design. Ultraflon™ 500C bearings and a Tungsten Carbide pin provide exceptional wear resistance.The Signet 2540 Paddlewheel Flow Sensor offers field-replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (i.e. lightning) sometimes encountered in field wiring. Sensors can be installed in DN40 to DN600 (1½ to 24 in.) pipes using the 1½ inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve service without process shutdown in pipes up to DN900 (36 in.). Both styles of sensors must be used in full pipes and can be used in low pressure systems.


  • Rotor-X Paddlewheel Flow Sensor
    Rotor-X Paddlewheel Flow Sensor
    515

    Simple to install with time-honored reliable performance, Signet Model 515 Rotor-X Paddlewheel Flow Sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The output signal of the Model 515 is a sinusoidal frequency capable of driving a self-powered flowmeter (Model 5090). The wide dynamic flow range of 0.3 to 6 m/s (1 to 20 ft/s) allows the sensor to measure liquid flow rates in full pipes and can be used in low pressure systems.The Signet Model 515 sensors are offered in a variety of materials for a wide range of pipe sizes and insertion configurations. The many material choices, including PP and PVDF, make this model highly versatile and chemically-compatible to many liquid process solutions. Sensors can be installed in up to DN900 (36 in.) pipes using Signet's comprehensive line of custom fittings. These custom fittings, which include tees, saddles, and weld lets, set the sensor to the proper insertion depth into the process flow. The sensors are also offered in configurations for wet-tap requirements.


  • Magmeter Flow Sensor
    Magmeter Flow Sensor
    2551

    The Signet 2551 Magmeter is an insertion-style magnetic flow sensor that features no moving parts. The patented sensor design is available in corrosion-resistant materials to provide long-term reliability with minimal maintenance costs. Material options include PP with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium. Utilizing the comprehensive line of Signet installation fittings, sensor alignment and insertion depth is automatic. These versatile, simple-to-install sensors deliver accurate flow measurement over a wide dynamic range in pipe sizes ranging from DN15 to DN900 (½ to 36 in.), satisfying the requirements of many diverse applications.


  • Flow Transmitter
    Flow Transmitter
    AFM

    The AFM series flow transmitter can be compatible with electromagnetic, peddlewheel, turbine, or mechanical flow sensors. It is easy to setup without complicated procedure. Only entering K factor or accumulated pulse value is sufficient to get correct reading. To define time frame and unit, it can also convert and get instant flow rate and flow volumn. Product features: -Time for instant and accumulated volume can be programmed by day, by hour, by minute or by second. - Unit can be selected from: instant flow rate: GPM (L, M3) / accumulated flow rate: G, L, M3 - 2 sets of accumulated value, one can be cleared and recounting, the other is permanent value. - Designed with industrial standard housing (96 x 96mm),which is suitable for standard industrial control panel. - Equipped with power outage recoring function - CE approved.


  • pH/ORP Electrodes
    pH/ORP Electrodes
    2724, 2725, 2726

    The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway is constructed to increase the total reference effectiveness and ensures long service life. The 2724-2726 electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾" NPT or ISO 7-1 R¾ threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings.


  • Two-Wire Isolated Temperature Transmitter
    Two-Wire Isolated Temperature Transmitter
    ATR-3

    Isolation is avaliable to ATR series temperature transducer, in order to avoid interference. It can be used with different temperature sensors, such as thermal resistance (PT100, PT500, PT1000) and provide 4-20mA output. The installation will be directly mounted on head of temperature sensors. UPSCALE temperature sensor probe disconnection protection and alarm function are available. Temperature signal and range can be configured. LED signal light are equipped for power and function infication. It is CE approved and the protection rate is IP65.


  • Two-Wire Isolated Temperature Transmitter (Thermocouple/Pt sensor)
    Two-Wire Isolated Temperature Transmitter (Thermocouple/Pt sensor)
    ATR-5

    Isolation is avaliable to ATR-5 series temperature transducer, in order to avoid interference. It can be used with different temperature sensors, such as thermal resistance (PT100, PT500, PT1000) and thermocouple (J. K. T. E. B. R. S. N. C.) and provide 4-20mA and RS485 output. The installation will be directly mounted on head of temperature sensors. UPSCALE temperature sensor probe disconnection protection and alarm function are available. Temperature signal and range can be configured. LED signal light are equipped for power and function infication. It is CE approved and the protection rate is IP68.



Result 1 - 17 of 17