Environmental sensing, liquid measurement and analysis.

Best Sale

Liquid Measurement | Automation System & Control | Industrial Equipment Supplier - Aecl

Based in Taiwan, Autotronic Enterprise Co., Ltd. is an industrial equipment supplier of automation system controllers and signal converters since 1976.

As an industrial equipment supplier of automation environmental sensing, liquid measurement and analysis, Aecl provides total automation system control solutions particularly for air quality and temperature & humidity automation control fields. Flow control devices such as paddlewheels, magnetic and turbines, environment measurement equipment such as temperature & humidity transmitters, heat (BTU) meters & calculators and ultrasonic flowmeters, and GF valves and GF signet as a distributor in Taiwan.

Aecl has been offering customers high-quality and reliable automation system controllers, signal converter manufacturing and control systems, analyzers and automation solutions with professionalism. Both with advanced technology and 40 years of experience, Aecl ensures each customer's demands are met.

Result 1 - 24 of 112
SpecificationAction
Temperature / humidity / dew point transmitter
Temperature / humidity / dew point transmitter

Measurement: Temperature/ Humidity/ Dew point Measurement principle: CMOSens sensor technology Measurement range:   Temperature:0~100℃/ 0~50℃/ -50~+50℃(Analog) ; -40℃~100℃(RS485 Modbus RTU)   Humidity: 0~100%RH Outputs:   DC 4~20mA   DC 0~10V/ 0~5V/ 1~5V   RS-485 (Modbus RTU) Power supply:   20~36V DC (Output: 0~10V/0~5V/1~5V);   12 ~ 36V DC (Output:4~20mA, RS485);   AC 24V (50/60Hz) Optional bright LCD display CE & FCC Certification Maintenance-free for normal indoor applications

More
Temperature and humidity transmitter for high humidity environment
Temperature and humidity transmitter for high humidity environment

Measurement: Temperature and Humidity Measurement principle: CMOSens sensor technology Measurement range: Temperature:   0~100℃/ 0~50℃/ -50~+50℃ (Analog)   -40~100℃ (RS485 Modbus RTU) Humidity:0~100%RH Outputs:   DC 4~20mA   DC 0~10V/ 0~5V/ 1~5V   RS-485 (RS485 Modbus RTU) Power supply:   12 ~ 35V DC (output: 0~10V/0~5V/1~5V, RS485)   15 ~ 35V DC (output: 4~20 mA)   AC 24V Installations: Duct-mount/ Separated/ Outside Air Protection: IP65 Optional bright LCD display CE & FCC Certification Maintenance-free for normal indoor applications

More
Thermostat / Humidistat
Thermostat / Humidistat

Control mode: Dehumidification/ Humidification/ Heating/ Cooling/ Dehumidification&Cooling Control: one-stage/ two-stage Measurement: Temperature & Humidity Signal output: Relay (10A / 250 VAC) Sensing element: CMOS sensor Measurement Range:   Temperature: -40℃ ~ 99℃   Humidity: 0~99%RH Housing material: Plastic (ABS), Flame retardant acc. to UL94-V2 Installation: Wall-mount / Separated Protection:   Transmitter: IP30   Probe of separated type: IP65 Optional bright LCD display CE & FCC Certification Maintenance-free for normal indoor applications

More
CO2, temperature and RH Display
CO2, temperature and RH Display

Measurements: CO2, Humidity, Temperature Clock and calendar: Real time clock and calendar Measurement range:   CO2: 0 ~ 9999 ppm   Humidity: 0 ~ 95 %RH   Temperature: -10 ~ 60°C Power Supply: 12 VDC (supply with an AC adapter 100 ~ 240V / 50 ~ 60Hz) Display: 7 segment LED display Installation: wall-mount Output signal:RS485 (Modbus RTU) Alarm output: 3 Relay outputs can be specified as CO2, relative humidity, or temperature N.O. and N.C. (2A/30VDC) Dimensions (mm): 527 x 217 x 32 Maintenance-free for normal indoor applications CE & FCC Certification Customized specification is available upon request

More
CO2, PM2.5, RH and Temperature display
CO2, PM2.5, RH and Temperature display

Measurements: CO2, PM2.5, Humidity, Temperature Clock and calendar: Real time clock and calendar Measurement range:   CO2: 0 ~ 9999 ppm   PM2.5: 0~ 600 μg/m3   Humidity: 0 ~ 95 %RH   Temperature: -10 ~ 60°C Power Supply: 12 VDC (supply with an AC adapter 100 ~ 240V / 50 ~ 60Hz) Display: 7 segment LED display Installation: wall-mount Output signal:RS485 (Modbus RTU) Alarm output: 3 Relay outputs can be specified as CO2, PM2.5, relative humidity, or temperature N.O. and N.C. (2A/30VDC) Dimensions (mm): 527 x 217 x 32 Maintenance-free for normal indoor applications CE & FCC Certification Customized specification is available upon request

More
CO2, temperature and humidity transmitter
CO2, temperature and humidity transmitter

Measurement: Carbon Dioxide, temperature and humidity Measurement principle: CO2: Gold-plated infrared (NDIR) wave-guide Temperature and humidity: CMOSens technology Measurement range:   CO2: 0 ~ 2,000 ppm (Standard)   Temperature: -10℃~60℃   Humidity: 0~95%RH Output signal: RS-485 (Modbus RTU) Power supply: DC 12 ~ 36V, AC 24V (50/60Hz) Installations: Wall-mount / Duct-mount Protection:   Wall-mount: IP30   Duct-mount: IP65 Optional bright LCD display CE & FCC & VCCI Certification Maintenance-free for normal indoor applications

More
Carbon Dioxide Transmitter
Carbon Dioxide Transmitter
More
CO2 transmitter for high humidity
CO2 transmitter for high humidity

Measurement: Carbon Dioxide Measurement principle: Gold-plated infrared (NDIR) wave-guide technology Measurement range: 0 ~ 9999 ppm Outputs:   DC 4 ~ 20mA   RS485 (Modbus RTU) Power supply: 12 ~ 36V AC/DC,50/60 Hz (half-wave rectifier input) Installations: Wall-mount Dimensions (mm): 86.05 x 69.12 x 59.75 Protection: IP54 Case Material: Stainless

More
Carbon Monoxide Transmitter
Carbon Monoxide Transmitter

Measurement: Carbon Monoxide Measurement principle: Chemical-electro Measuring range:   Switchable measurement range: 0~100ppm/ 0~250ppm   Optional measurement range:30~1000ppm Signal output:   DC 4 ~ 20mA   DC 0 ~ 10 V (Switchable)   RS-485 (Modbus RTU) Alarm output: Relay output N.O, N.C (2A / 30V DC ) ; Relay setting 50 ppm Protection rate: IP30 Installation: Wall-mount Dimensions(mm): 113.57 x 80 x 28.79 Optional LCD display CE certification Maintenance-free for normal indoor applications

More
PM2.5 Transmitter
PM2.5 Transmitter

Measurement: PM2.5 Measurement principle: Laser scattering Measurement range: 0~ 600 μg/m3 Output signal: RS-485 (Modbus RTU), Power supply: DC 12V~36V, AC 24V(50/60Hz) Installation: wall-mount Dimensions (mm): 113.57 × 80 × 28.79 Optional bright LCD display CE & FCC certification Maintenance-free for normal indoor applications

More
PM10 Air Quality Transmitter
PM10 Air Quality Transmitter

Measurement: PM10 Measurement principle: Laser scattering Measurement range: 0~ 600 μg/m3 Output signal:RS-485 (Modbus RTU), Power supply: DC 12V~36V, AC 24V(50/60Hz) Installation: wall-mount Dimensions (mm): 113.57 × 80 × 28.79 Optional bright LCD display CE & FCC Certification Maintenance-free for normal indoor applications

More
HCHO Transmitter
HCHO Transmitter

Measurement: HCHO Measurement principle: Electro-chemical Measurement range: 0 ~ 3 ppm Output signal:RS-485 (Modbus RTU) Power supply: DC 12V~36V, AC 24V(50/60Hz) Installations: Wall-mount Dimensions (mm): 113.57×80.00×28.79 Optional bright LCD display CE Certification Maintenance-free for normal indoor applications

More
TVOC Air Quality Transmitter
TVOC Air Quality Transmitter

Measurement: Total volatile organic compound(TVOC) Measurement principle: MEMS metal oxide Measurement range: 125~600ppb Output signal: RS-485 (Modbus RTU) Power supply: DC 12V~36V, AC 24V(50/60Hz) Installations: Wall-mount Dimensions (mm): 113.57×80.00×28.79 Optional bright LCD display CE Certification Maintenance-free for normal indoor applications

More
Oxygen Transmitter
Oxygen Transmitter

Measurement: Oxygen Measurement principle: Electrochemical Measurement range: 0 ~ 30% Power supply DC 12 ~36V, AC 24V (50/60Hz) Signal outputs:   RS485 (Modbus RTU),   4~20mA/2~10V (switchable) Protection rate: IP30 Dimensions (mm): 113.57 × 80 × 28.79 Installation: wall-mount Optional LCD display CE certification Maintenance-free for normal indoor applications

More
Differential Pressure Transmitter
Differential Pressure Transmitter

Media compatibility : air, N2, O2 Measurement principle: Thermal flow-through principal Measurement range: -25~25 Pa/ -125~125 Pa/ -500~500 Pa (Optional) Power supply: 12 ~ 36V AC/DC,50/60Hz Signal outputs:   DC 4 ~ 20mA (Loading resistance ≦500Ω)   DC 0 ~ 10 V(Loading resistance ≧50KΩ)   RS485 (Modbus RTU) Offset stability: < 0.1 pa/ yr. Protection rate:IP54 Cast Material: Cast aluminum Dimensions (mm): 98(H) x 64(W) x 34(D) Optional LCD display CE certification Maintenance-free for normal indoor applications

More
Lux Transmitter
Lux Transmitter

Measurement: Illumination Measurement principle: Optical Measurement range: 0 ~ 9999 Lux Output signal: RS-485 (Modbus RTU) Power supply: DC 12 ~ 36V, AC 24V (50/60Hz) Installations: Wall-mount Dimensions (mm): 113.57×80×28.79 Optional bright LCD display Maintenance-free for normal indoor applications

More
LoRa temperature and humidity transmitter
LoRa temperature and humidity transmitter

Measurement: Temperature/ Humidity Measurement principle: CMOSens sensor technology Measurement range:   Temperature:0~100℃/ 0~50℃/ -50~+50℃(Analog) ; -40℃~100℃(RS485)   Humidity:0~100%RH Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: 12 ~ 36V DC; AC 24V (50/60Hz) Optional bright LCD display Maintenance-free for normal indoor applications CE certification

More
LoRa CO2, PM2.5, RH and Temperature display
LoRa CO2, PM2.5, RH and Temperature display

Measurements: CO2, PM2.5, Humidity, Temperature Clock and calendar: Real time clock and calendar Measurement range:   CO2: 0 ~ 9999 ppm   PM2.5: 0~ 600 μg/m3   Humidity: 0 ~ 95 %RH   Temperature: -10 ~ 60°C Power Supply: 12 VDC (supply with an AC adapter 100 ~ 240V / 50 ~ 60Hz) Display: 7 segment LED display Installation: wall-mount Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Alarm output: 3 Relay outputs can be specified as CO2, PM2.5, relative humidity, or temperature N.O. and N.C. (2A/30VDC) Dimensions (mm): 527 x 217 x 32 Weight: 2700g Maintenance-free for normal indoor applications CE certification

More
LoRa temperature, humidity and CO2 transmitter
LoRa temperature, humidity and CO2 transmitter

Measurement: Carbon Dioxide, temperature and humidity Measurement principle: CO2: Gold-plated infrared (NDIR) wave-guide Temperature and humidity: CMOSens technology Measurement range:   CO2: 0 ~ 2,000 ppm (Standard)   Temperature: -10℃~60℃   Humidity: 0~95%RH Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: DC 12 ~ 36V, AC 24V (50/60Hz) Optional bright LCD display Maintenance-free for normal indoor applications CE certification

More
LoRa Carbon Dioxide Transmitter
LoRa Carbon Dioxide Transmitter

Measurement: Carbon Dioxide Measurement principle: Gold-plated infrared (NDIR) wave-guide technology Measurement range:   0 ~ 2,000 ppm (Standard)   0 ~ 9999 ppm (High level) Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: DC 12V~36V, AC 24V(50/60Hz) Installations:   Wall-mount Dimensions (mm):   Wall-mount: 113.57(H) x 80(W) x 28.79(D) Protection:   Wall-mount:IP30 Optional bright LCD display Maintenance-free for normal indoor applications

More
LoRa Carbon Monoxide Transmitter
LoRa Carbon Monoxide Transmitter

Measurement: Carbon Monoxide Measurement principle: Chemical-electro Measuring range:   Switchable measurement range: 0~100ppm/ 0~250ppm   Optional measurement range:30~1000ppm Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Alarm output: Relay output N.O, N.C (2A / 30V DC) ; Relay setting 50 ppm Protection rate: IP30 Installation: Wall-mount Dimensions(mm): 113.57 x 80 x 28.79 Optional LCD display CE certification Maintenance-free for normal indoor applications

More
LoRa PM2.5 Transmitter
LoRa PM2.5 Transmitter

Measurement: PM2.5 Measurement principle: Laser scattering Measurement range: 0~ 600 μg/m3 Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: DC 12V~36V, AC 24V(50/60Hz) Installation: wall-mount Dimensions (mm): 113.57 × 80 × 28.79 Optional bright LCD display CE & FCC certification Maintenance-free for normal indoor applications

More
LoRa PM10 Air Quality Transmitter
LoRa PM10 Air Quality Transmitter

Measurement: PM10 Measurement principle: Laser scattering Measurement range: 0~ 600 μg/m3 Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: DC 12V~36V, AC 24V(50/60Hz) Installation: wall-mount Dimensions (mm): 113.57 × 80 × 28.79 Optional bright LCD display CE & FCC Certification Maintenance-free for normal indoor applications

More
LoRa HCHO Transmitter
LoRa HCHO Transmitter

Measurement: HCHO Measurement principle: Electro-chemical Measurement range: 0 ~ 3 ppm Output signal: switchable RS485/LoRa (The frequency can be configured accordingly from 862 to 932Hz) Protocol: Modbus RTU Power supply: DC 12V~36V, AC 24V(50/60Hz) Installations: Wall-mount Dimensions (mm): 113.57×80.00×28.79 Optional bright LCD display CE Certification Maintenance-free for normal indoor applications

More

Result 1 - 24 of 112